Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215.381
Filtrar
1.
World J Gastroenterol ; 30(12): 1663-1669, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38617743

RESUMEN

Liver disease accounts for approximately 2 million deaths per year worldwide. All chronic liver diseases (CLDs), whether of toxic, genetic, autoimmune, or infectious origin, undergo typical histological changes in the structure of the tissue. These changes may include the accumulation of extracellular matrix material, fats, triglycerides, or tissue scarring. Noninvasive methods for diagnosing CLD, such as conventional B-mode ultrasound (US), play a significant role in diagnosis. Doppler US, when coupled with B-mode US, can be helpful in evaluating the hemodynamics of hepatic vessels and detecting US findings associated with hepatic decompensation. US elastography can assess liver stiffness, serving as a surrogate marker for liver fibrosis. It is important to note that interpreting these values should not rely solely on a histological classification. Contrast-enhanced US (CEUS) provides valuable information on tissue perfusion and enables excellent differentiation between benign and malignant focal liver lesions. Clinical evaluation, the etiology of liver disease, and the patient current comorbidities all influence the interpretation of liver stiffness measurements. These measurements are most clinically relevant when interpreted as a probability of compensated advanced CLD. B-mode US offers a subjective estimation of fatty infiltration and has limited sensitivity for mild steatosis. The controlled attenuation parameter requires a dedicated device, and cutoff values are not clearly defined. Quan-titative US parameters for liver fat estimation include the attenuation coefficient, backscatter coefficient, and speed of sound. These parameters offer the advantage of providing fat quantification alongside B-mode evaluation and other US parameters. Multiparametric US (MPUS) of the liver introduces a new concept for complete noninvasive diagnosis. It encourages examiners to utilize the latest features of an US machine, including conventional B-mode, liver stiffness evaluation, fat quantification, dispersion imaging, Doppler US, and CEUS for focal liver lesion characterization. This comprehensive approach allows for diagnosis in a single examination, providing clinicians worldwide with a broader perspective and becoming a cornerstone in their diagnostic arsenal. MPUS, in the hands of skilled clinicians, becomes an invaluable predictive tool for diagnosing, staging, and monitoring CLD.


Asunto(s)
Hígado Graso , Hepatopatías , Humanos , Hepatopatías/diagnóstico por imagen , Ultrasonografía , Cirrosis Hepática/diagnóstico por imagen
2.
Eur J Histochem ; 68(2)2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38619113

RESUMEN

Knowledge of the structure of the face is of fundamental importance. In fact, the face is treated in many areas of medicine, from dermatology, to maxillofacial surgery, to otorhinolaryngology, to ophthalmology, etc. and anti-aging aesthetic treatments, and those for the resolution of blemishes are on the increase. For ethical reasons it is not possible to take biopsy samples for facial analysis in the aesthetic field. The main aim of this study was to demonstrate that a high-resolution bimodal ultrasound examination, combined with elastosonography, could be a valid tool for pre-treatment morphological evaluation. To achieve this goal, skin samples were taken from the forehead, zygomatic area, nasolabial fold, upper and lower lip from cadavers to histologically characterize their structure. Subsequently, these same areas were evaluated in vivo using conventional B-mode ultrasound with a 24 MHz high-frequency probe, and elastosonography. The data obtained with the different techniques were compared, in order to state that modern ultrasound techniques can provide similar histological information. The analysis showed that the superficial hypodermis presented a different shape and structure in the different areas, with the exception of the areas of the upper and lower lip, which appeared similar. With aging, the forehead and zygomatic area showed a volumetric increase in the superficial hypodermic layer, while the lip showed non-structural changes. The morphology of the nasolabial fold remained unchanged. When it is not possible to perform histological investigations on the face, to understand its characteristics and dynamics, ultrasound with a 24 MHz probe would seem to be the most suitable method, while elastosonography could be a valid method for evaluating the stiffness of the structural components.


Asunto(s)
Labio , Tejido Subcutáneo , Ultrasonografía
3.
Acta Neurochir (Wien) ; 166(1): 177, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622368

RESUMEN

PURPOSE: In general, high levels of PEEP application is avoided in patients undergoing craniotomy to prevent a rise in ICP. But that approach would increase the risk of secondary brain injury especially in hypoxemic patients. Because the optic nerve sheath is distensible, a rise in ICP is associated with an increase in the optic nerve sheath diameter (ONSD). The cutoff value for elevated ICP assessed by ONSD is between 5.6 and 6.3 mm. We aimed to evaluate the effect of different PEEP levels on ONSD and compare the effect of different PEEP levels in patients with and without intracranial midline shift. METHODS: This prospective observational study was performed in aged 18-70 years, ASA I-III, 80 patients who were undergoing supratentorial craniotomy. After the induction of general anesthesia, the ONSD's were measured by the linear transducer from 3 mm below the globe at PEEP values of 0-5-10 cmH2O. The ONSD were compered between patients with (n = 7) and without midline shift (n = 73) at different PEEP values. RESULTS: The increases in ONSD due to increase in PEEP level were determined (p < 0.001). No difference was found in the comparison of ONSD between patients with and without midline shift in different PEEP values (p = 0.329, 0.535, 0.410 respectively). But application of 10 cmH2O PEEP in patients with a midline shift increased the mean ONSD value to 5.73 mm. This value is roughly 0.1 mm higher than the lower limit of the ONSD cutoff value. CONCLUSIONS: The ONSD in adults undergoing supratentorial tumor craniotomy, PEEP values up to 5 cmH2O, appears not to be associated with an ICP increase; however, the ONSD exceeded the cutoff for increased ICP when a PEEP of 10 cmH2O was applied in patients with midline shift.


Asunto(s)
Hipertensión Intracraneal , Adulto , Humanos , Hipertensión Intracraneal/etiología , Hipertensión Intracraneal/cirugía , Nervio Óptico/cirugía , Nervio Óptico/diagnóstico por imagen , Presión Intracraneal/fisiología , Ultrasonografía/efectos adversos , Craneotomía/efectos adversos , Respiración con Presión Positiva/efectos adversos
4.
BMC Med Imaging ; 24(1): 89, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622546

RESUMEN

BACKGROUND: Accurate preoperative identification of ovarian tumour subtypes is imperative for patients as it enables physicians to custom-tailor precise and individualized management strategies. So, we have developed an ultrasound (US)-based multiclass prediction algorithm for differentiating between benign, borderline, and malignant ovarian tumours. METHODS: We randomised data from 849 patients with ovarian tumours into training and testing sets in a ratio of 8:2. The regions of interest on the US images were segmented and handcrafted radiomics features were extracted and screened. We applied the one-versus-rest method in multiclass classification. We inputted the best features into machine learning (ML) models and constructed a radiomic signature (Rad_Sig). US images of the maximum trimmed ovarian tumour sections were inputted into a pre-trained convolutional neural network (CNN) model. After internal enhancement and complex algorithms, each sample's predicted probability, known as the deep transfer learning signature (DTL_Sig), was generated. Clinical baseline data were analysed. Statistically significant clinical parameters and US semantic features in the training set were used to construct clinical signatures (Clinic_Sig). The prediction results of Rad_Sig, DTL_Sig, and Clinic_Sig for each sample were fused as new feature sets, to build the combined model, namely, the deep learning radiomic signature (DLR_Sig). We used the receiver operating characteristic (ROC) curve and the area under the ROC curve (AUC) to estimate the performance of the multiclass classification model. RESULTS: The training set included 440 benign, 44 borderline, and 196 malignant ovarian tumours. The testing set included 109 benign, 11 borderline, and 49 malignant ovarian tumours. DLR_Sig three-class prediction model had the best overall and class-specific classification performance, with micro- and macro-average AUC of 0.90 and 0.84, respectively, on the testing set. Categories of identification AUC were 0.84, 0.85, and 0.83 for benign, borderline, and malignant ovarian tumours, respectively. In the confusion matrix, the classifier models of Clinic_Sig and Rad_Sig could not recognise borderline ovarian tumours. However, the proportions of borderline and malignant ovarian tumours identified by DLR_Sig were the highest at 54.55% and 63.27%, respectively. CONCLUSIONS: The three-class prediction model of US-based DLR_Sig can discriminate between benign, borderline, and malignant ovarian tumours. Therefore, it may guide clinicians in determining the differential management of patients with ovarian tumours.


Asunto(s)
Aprendizaje Profundo , Neoplasias Ováricas , Humanos , Femenino , 60570 , Neoplasias Ováricas/diagnóstico por imagen , Ultrasonografía , Algoritmos , Estudios Retrospectivos
5.
Med Sci Monit ; 30: e942780, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38627942

RESUMEN

BACKGROUND Diaphragmatic thickness fraction (DTF), measured by ultrasound, can predict the occurrence of postoperative residual neuromuscular blockade (RNMB). We hypothesized that the utilization of diaphragmatic ultrasound during the postoperative awakening phase of anesthesia in patients offers a successful means of avoiding RNMB in a notably comfortable manner, as compared to the use of acceleromyograph. MATERIAL AND METHODS Patients who underwent elective thyroid cancer radical surgery were enrolled in this prospective clinical study. Eligible participants were randomly assigned to 1 of 3 groups: 1) combined ultrasonography with acceleromyography group (the US+AMG group), 2) the AMG group, or 3) the usual clinical practice group (the UCP group). The primary outcomes of the study were the incidence of RNMB and hypoxemia after tracheal extubation. RESULTS The study included a total of 127 patients (43 in the US+AMG group, 44 in the AMG group, and 40 in the UCP group). The incidence of RNMB and hypoxemia was higher in the UCP group than in the US+AMG and AMG groups at 15 and 30 min after extubation, respectively. The mean area under the receiver operating characteristic curve, and the decision curve of the recovery rate of DTF (DTF) was greater than that of DTF. CONCLUSIONS The use of diaphragm ultrasound during the postoperative awakening phase of anesthesia can significantly reduce the incidence of RNMB. This method was non-inferior to the use of AMG during the entire perioperative period.


Asunto(s)
Retraso en el Despertar Posanestésico , Bloqueo Neuromuscular , Humanos , Bloqueo Neuromuscular/métodos , Estudios Prospectivos , Recuperación de la Función , Retraso en el Despertar Posanestésico/epidemiología , Anestesia General , Hipoxia , Ultrasonografía
6.
J Helminthol ; 98: e34, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38628145

RESUMEN

The diagnosis of cystic echinococcosis (CE) is based on imaging. Detection of a focal lesion with morphological characteristics of Echinococcus granulosus sensu lato metacestode is the starting point for the diagnostic workup. In organs explorable with ultrasound (US), this is the method of choice for both aetiological diagnosis of CE and staging of the CE cyst. Staging in terms of lesion morphology is also needed when serology is added to the diagnostic workflow when imaging alone is inconclusive. Finally, staging guides the clinical management of uncomplicated CE, especially in the liver. This commentary provides an overview of the most up-to-date evidence backing the above-mentioned role of US in the diagnosis and clinical management of CE. Finally, we outline future perspectives for the improvement of CE diagnosis.


Asunto(s)
Equinococosis , Echinococcus granulosus , Animales , Equinococosis/diagnóstico por imagen , Ultrasonografía , Hígado/diagnóstico por imagen
7.
Tech Coloproctol ; 28(1): 44, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38561492

RESUMEN

BACKGROUND: Imaging is vital for assessing rectal cancer, with endoanal ultrasound (EAUS) being highly accurate in large tertiary medical centers. However, EAUS accuracy drops outside such settings, possibly due to varied examiner experience and fewer examinations. This underscores the need for an AI-based system to enhance accuracy in non-specialized centers. This study aimed to develop and validate deep learning (DL) models to differentiate rectal cancer in standard EAUS images. METHODS: A transfer learning approach with fine-tuned DL architectures was employed, utilizing a dataset of 294 images. The performance of DL models was assessed through a tenfold cross-validation. RESULTS: The DL diagnostics model exhibited a sensitivity and accuracy of 0.78 each. In the identification phase, the automatic diagnostic platform achieved an area under the curve performance of 0.85 for diagnosing rectal cancer. CONCLUSIONS: This research demonstrates the potential of DL models in enhancing rectal cancer detection during EAUS, especially in settings with lower examiner experience. The achieved sensitivity and accuracy suggest the viability of incorporating AI support for improved diagnostic outcomes in non-specialized medical centers.


Asunto(s)
Aprendizaje Profundo , Neoplasias del Recto , Humanos , Endosonografía/métodos , Ultrasonografía/métodos , Redes Neurales de la Computación , Neoplasias del Recto/diagnóstico por imagen
9.
Emergencias ; 36(2): 109-115, 2024 Apr.
Artículo en Español, Inglés | MEDLINE | ID: mdl-38607306

RESUMEN

OBJECTIVES: To study the diagnostic performance of an ultrasound-based algorithm that includes the deceleration time (DT) of early mitral filling to establish a diagnosis of acute heart failure (AHF) in patients who come to an emergency department because of dyspnea. MATERIAL AND METHODS: Prospective analysis in a convenience sample of patients who came to a hospital emergency department with acute dyspnea. The algorithm included ultrasound findings and 4 echocardiographic findings as follows: mitral annular plane systolic excursion, Doppler mitral flow velocity, tissue Doppler imaging measure of the lateral annulus, and the DT of early mitral filling. The definitive diagnosis was made by 2 physicians blinded to each other's diagnosis and the ultrasound findings. RESULTS: A total of 166 adult patients with a mean (SD) age of 76 (13) years were included; 79 (48%) were women. AHF was the definitive diagnosis in 62 patients (37%). Diagnostic agreement was good between the 2 physicians (κ = 0.71). The algorithm classified all the patients, and there were no undetermined diagnoses. Diagnostic performance indicators for the ultrasound-based algorithm integrating early DT findings were as follows: area under the receiver operating characteristic curve, 0.91 (95% CI, 0.86-0.96); sensitivity, 87% (95% CI, 76%-94%); specificity, 95% (95% CI, 89%-98%); positive likelihood ratio, 18.1 (95% CI, 7.7-42.8); and negative likelihood ratio, 0.14 (95% CI, 0.07-0.26). CONCLUSION: The ultrasound-based algorithm integrating the DT of early mitral filling performs well for diagnosing AHF in emergency patients with dyspnea. The inclusion of early DT allows all patients to be diagnosed.


OBJETIVO: Analizar el rendimiento diagnóstico de un algoritmo ecográfico que incluye el tiempo de desaceleración precoz del flujo mitral (TD) para establecer el diagnóstico de insuficiencia cardiaca aguda (ICA) en pacientes que consultan en un servicio de urgencias hospitalario (SUH) por disnea. METODO: Análisis prospectivo de una muestra de conveniencia de pacientes que consultan por disnea aguda en un SUH. El algoritmo ecográfico incluyó la ecografía pulmonar y cuatro parámetros ecocardiográficos, se midió MAPSE (desplazamiento sistólico del plano del anillo mitral), medidas doppler de flujo mitral, medidas doppler tisular en el anillo mitral lateral y TD. El diagnóstico final fue asignado por 2 médicos ciegos entre sí y a los hallazgos ecográficos. RESULTADOS: Se incluyeron 166 pacientes adultos, la edad media fue de 76 años (DE 13) y 79 eran mujeres (48%). Hubo 62 pacientes (37%) con un diagnóstico final de ICA. La concordancia entre asignadores fue buena para el diagnóstico de ICA (κ = 0,71). El algoritmo clasificó a todos los pacientes, no hubo ningún diagnóstico indeterminado. El rendimiento diagnóstico del algoritmo mostró un área bajo la curva de 0,91 (IC 95%: 0,86-0,96), sensibilidad del 87% (IC 95%: 76%-94%), especificidad del 95% (IC 95%: 89%-98%), razón de verosimilitud positiva del 18,1 (IC 95%: 7,7-42,8), razón de verosimilitud negativa del 0,14 (IC 95%: 0,07-0,26). CONCLUSIONES: Un algoritmo ecográfico que incluye el TD tiene un buen rendimiento para el diagnóstico de ICA en pacientes que acuden a SUH por disnea. Además, el uso de TD permite clasificar a todos los pacientes.


Asunto(s)
Servicio de Urgencia en Hospital , Insuficiencia Cardíaca , Adulto , Humanos , Femenino , Anciano , Masculino , Ultrasonografía , Algoritmos , Disnea/diagnóstico por imagen , Disnea/etiología , Insuficiencia Cardíaca/diagnóstico por imagen
10.
Sensors (Basel) ; 24(7)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38610578

RESUMEN

The aim of this paper is to investigate technological advancements made to a robotic tele-ultrasound system for musculoskeletal imaging, the MSK-TIM (Musculoskeletal Telerobotic Imaging Machine). The hardware was enhanced with a force feedback sensor and a new controller was introduced. Software improvements were developed which allowed the operator to access ultrasound functions such as focus, depth, gain, zoom, color, and power Doppler controls. The device was equipped with Wi-Fi network capability which allowed the master and slave stations to be positioned in different locations. A trial assessing the system to scan the wrist was conducted with twelve participants, for a total of twenty-four arms. Both the participants and radiologist reported their experience. The images obtained were determined to be of satisfactory quality for diagnosis. The system improvements resulted in a better user and patient experience for the radiologist and participants. Latency with the VPN configuration was similar to the WLAN in our experiments. This research explores several technologies in medical telerobotics and provides insight into how they should be used in future. This study provides evidence to support larger-scale trials of the MSK-TIM for musculoskeletal imaging.


Asunto(s)
Sistema Musculoesquelético , Robótica , Humanos , Ultrasonografía , Sistema Musculoesquelético/diagnóstico por imagen , Articulación de la Muñeca , Programas Informáticos
12.
Medicine (Baltimore) ; 103(15): e37768, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38608080

RESUMEN

BACKGROUND: Using meta-analysis to evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS) in the diagnosis of papillary thyroid microcarcinoma (PTMC). METHODS: For this systematic review and meta-analysis, we searched PubMed, Cochrane Library, Web of Science, WanFang Data, VPCS Data, and China National Knowledge Infrastructure electronic databases for diagnostic studies on PTMC by CEUS from January 2013 to November 2022. Data were not available or incomplete such as case reports, nonhuman studies, etc, were excluded. Random-effects meta-analyses were used to evaluate the diagnostic accuracy of CEUS in diagnosing PTMC. The quality of the evidence was assessed with the QUADAS-2 scale. This study is registered on PROSPERO, number CRD42023409417. RESULTS: Of 1064 records identified, 33 were eligible. The results showed that the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio of CEUS in diagnosing PTMC were 0.84 (95% confidence interval [CI] = 0.83-0.86), 0.82 (95% CI = 0.80-0.83), 3.90 (95% CI = 3.23-4.72), 0.21 (95% CI = 0.18-0.25), and 20.01 (95% CI = 14.97-26.74), respectively, and the area under the summary receiver operating characteristic curve was 0.8930 (the Q index was 0.8239). The Deek funnel plot indicated publication bias (P ˂.01). CONCLUSION: This meta-analysis provides an overview of diagnostic accuracy of CEUS in diagnosing PTMC which indicates CEUS has a good diagnostic value for PTMC. The limitations of this study are publication bias and strong geographical bias.


Asunto(s)
Carcinoma Papilar , Neoplasias de la Tiroides , Humanos , Ultrasonografía , Carcinoma Papilar/diagnóstico por imagen , China , Bases de Datos Factuales
13.
Med Eng Phys ; 126: 104153, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38621850

RESUMEN

The Iterative Close Point (ICP) algorithm is used for bone registrations based on ultrasound measurements. However, the ICP has been shown to suffer from local minima. The Complex optimization, as a more robust routine compared to the commonly used gradient-based algorithms, could be an alternative for solving the ICP problem. In this study, we investigated the effect of the initial estimate and the number of registration points on bone registrations achieved using the ICP and a Complex optimization routine and we compared it against using Quadratic Sequential Programming (SQP). Ultrasound measurements were performed with an A-mode probe on a bovine humerus and an ovine femur embedded into ballistic gel. Simultaneously, the bones and the probe were tracked in 3D space using retroreflective markers. Kinematic, ultrasound and geometrical data obtained from scans of the specimens and the probe served as input to a bone registrations routine. Registrations were performed using two ICP solvers for different initial estimates and number of registration points. On average, 68 % of the Complex optimization registrations had less than 1 mm translation error and less than 1° rotational error for perturbations of the initial estimate from the reference measurements compared to the 35 % of the SQP ones. Similar medians of registration errors were observed between the two methods for variations of the number of the employed registration points. Although the Complex optimization provided accurate bone registrations for all cases, the objective function could not always determine the registrations with the smallest registration error. Future research should explore methodologies to overcome this challenge.


Asunto(s)
Algoritmos , Huesos , Animales , Bovinos , Ovinos , Ultrasonografía , Huesos/diagnóstico por imagen , Fémur/diagnóstico por imagen , Extremidad Inferior , Imagenología Tridimensional/métodos
14.
BMC Geriatr ; 24(1): 308, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38565979

RESUMEN

BACKGROUND: The postural control and abdominal muscles' automatic activity were found to be impaired in subjects with low back pain (LBP) during static activities. However, the studies are predominantly conducted on younger adults and a limited number of studies have evaluated abdominal muscles' automatic activity during dynamic standing activities in subjects with LBP. The present study investigated the automatic activity of abdominal muscles during stable and unstable standing postural tasks in older adults with and without LBP. METHODS: Twenty subjects with and 20 subjects without LBP were included. The thickness of the transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles was measured during rest (in supine), static, and dynamic standing postural tasks. To estimate automatic muscle activity, each muscle's thickness during a standing task was normalized to its thickness during the rest. Standing postural tasks were performed using the Biodex Balance System. RESULTS: The mixed-model analysis of variance revealed that task dynamicity significantly affected thickness change only in the TrA muscle (P = 0.02), but the main effect for the group and the interaction were not significantly different (P > 0.05). There were no significant main effects of the group, task dynamicity, or their interaction for the IO and EO muscles (P > 0.05). During dynamic standing, only the TrA muscle in the control group showed greater thickness changes than during the static standing task (P < 0.05). CONCLUSIONS: Standing on a dynamic level increased the automatic activity of the TrA muscle in participants without LBP compared to standing on a static level. Further research is required to investigate the effects of TrA muscle training during standing on dynamic surfaces for the treatment of older adults with LBP.


Asunto(s)
Dolor de la Región Lumbar , Humanos , Anciano , Dolor de la Región Lumbar/diagnóstico , Estudios Transversales , Contracción Muscular/fisiología , Músculos Abdominales/diagnóstico por imagen , Músculos Abdominales/fisiología , Posición de Pie , Ultrasonografía
15.
A A Pract ; 18(4): e01772, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38569142

RESUMEN

An interspinous spacer is a minimally invasive implantable device for the treatment of lumbar spinal stenosis. The in situ implant may prevent safe and successful spinal anesthesia because its position can obstruct the path of the spinal needle. Lumbar neuraxial ultrasonography has been shown to aid in performance of neuraxial anesthesia in patients with challenging anatomy. Currently, there are no reported cases of ultrasound-assisted spinal anesthesia in patients with interspinous spacers. We present a case in which ultrasonography assisted the successful administration of a spinal anesthetic by avoiding an indwelling lumbar interspinous spacer.


Asunto(s)
Anestesia Raquidea , Vértebras Lumbares , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Descompresión Quirúrgica , Prótesis e Implantes , Ultrasonografía
16.
Mymensingh Med J ; 33(2): 453-460, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38557525

RESUMEN

Treating breast abscess by conventional incision and drainage, followed by regular dressing with prolonged hospital stay, anesthesia, unsatisfactory scar and chances of developing milk fistula in lactating mother is unsatisfactory. Here we study the outcome of ultrasonogram guided multiple aspirations in non-admitted outpatient setup, for its effectiveness as a replacement of conventional surgery. This descriptive, prospective and observational study was carried out from July 2018 to December 2020 with purposive sampling of all cases of breast abscess in a secondary care hospital who underwent ultrasonogram guided aspiration and oral antibiotics, on multiple visits in outpatient department and followed up for three months to study outcome. Mean age of patient was 28.19 years. Fifteen (46.9%) were non-lactating women. The right breast 18(56.3%) and upper outer quadrant 8(25.0%) was affected slightly more. All cases had tender lump except one (3.1%) who had a non-tender lump, but 20(62.5%) had no maximum fluctuating point, usually found in abscesses of other parts of the body. Fever was not a common feature in 8(25.0%) patients and axillary lymph node was not palpable in 26(81.3%) patient. Eighteen (56.3%) patients had healthy nipple, 8(25%) patients had cracked and 5(15.6%) had retracted nipple 11(34.4%) with pus discharge from nipple. Mean duration of symptom was 7 days. Mean sonographic diameter was 5.53cm and volume was 21.09ml. Mean aspirated total volume was 28±10.5 ml. Fifteen (46.9%) patients required 3 aspirations, 10(31.3%) needed 4 aspirations. Success rate was 84.4%, while 25(78.1%) had no complications. Mean healing time in this study was 14 days. We conclude that multiple aspirations under ultrasonogram guidance in outpatient setup day care procedure, is equally effective as conventional surgery and also devoid of many avoidable complications, but meticulous evaluation and high suspicion of background pathology for non-responding case is crucial.


Asunto(s)
Absceso , Lactancia , Humanos , Femenino , Adulto , Absceso/diagnóstico por imagen , Absceso/terapia , Estudios Prospectivos , Pacientes Ambulatorios , Ultrasonografía , Drenaje/métodos
17.
Agri ; 36(2): 123-125, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38558403

RESUMEN

We aimed to share our experience with an abdominal wall hematoma that developed after an ultrasonography-guided TAP block performed for the palliation of chronic abdominal wall pain. Bleeding was successfully stopped with coil embolization.


Asunto(s)
Pared Abdominal , Bloqueo Nervioso , Humanos , Pared Abdominal/diagnóstico por imagen , Músculos Abdominales/diagnóstico por imagen , Bloqueo Nervioso/efectos adversos , Ultrasonografía , Hematoma/diagnóstico por imagen , Hematoma/etiología , Dolor Postoperatorio , Ultrasonografía Intervencional
18.
Opt Lett ; 49(7): 1725-1728, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38560847

RESUMEN

Ultrasound coupling is one of the critical challenges for traditional photoacoustic (or optoacoustic) microscopy (PAM) techniques transferred to the clinical examination of chronic wounds and open tissues. A promising alternative potential solution for breaking the limitation of ultrasound coupling in PAM is photoacoustic remote sensing (PARS), which implements all-optical non-interferometric photoacoustic measurements. Functional imaging of PARS microscopy was demonstrated from the aspects of histopathology and oxygen metabolism, while its performance in hemodynamic quantification remains unexplored. In this Letter, we present an all-optical thermal-tagging flowmetry approach for PARS microscopy and demonstrate it with comprehensive mathematical modeling and ex vivo and in vivo experimental validations. Experimental results demonstrated that the detectable range of the blood flow rate was from 0 to 12 mm/s with a high accuracy (measurement error:±1.2%) at 10-kHz laser pulse repetition rate. The proposed all-optical thermal-tagging flowmetry offers an effective alternative approach for PARS microscopy realizing non-contact dye-free hemodynamic imaging.


Asunto(s)
Técnicas Fotoacústicas , Tecnología de Sensores Remotos , Técnicas Fotoacústicas/métodos , Reología/métodos , Ultrasonografía/métodos , Microscopía/métodos
19.
BMC Med ; 22(1): 147, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38561764

RESUMEN

BACKGROUND: Thyroid nodule (TN) patients in China are subject to overdiagnosis and overtreatment. The implementation of existing technologies such as thyroid ultrasonography has indeed contributed to the improved diagnostic accuracy of TNs. However, a significant issue persists, where many patients undergo unnecessary biopsies, and patients with malignant thyroid nodules (MTNs) are advised to undergo surgery therapy. METHODS: This study included a total of 293 patients diagnosed with TNs. Differential methylation haplotype blocks (MHBs) in blood leukocytes between MTNs and benign thyroid nodules (BTNs) were detected using reduced representation bisulfite sequencing (RRBS). Subsequently, an artificial intelligence blood leukocyte DNA methylation (BLDM) model was designed to optimize the management and treatment of patients with TNs for more effective outcomes. RESULTS: The DNA methylation profiles of peripheral blood leukocytes exhibited distinctions between MTNs and BTNs. The BLDM model we developed for diagnosing TNs achieved an area under the curve (AUC) of 0.858 in the validation cohort and 0.863 in the independent test cohort. Its specificity reached 90.91% and 88.68% in the validation and independent test cohorts, respectively, outperforming the specificity of ultrasonography (43.64% in the validation cohort and 47.17% in the independent test cohort), albeit with a slightly lower sensitivity (83.33% in the validation cohort and 82.86% in the independent test cohort) compared to ultrasonography (97.62% in the validation cohort and 100.00% in the independent test cohort). The BLDM model could correctly identify 89.83% patients whose nodules were suspected malignant by ultrasonography but finally histological benign. In micronodules, the model displayed higher specificity (93.33% in the validation cohort and 92.00% in the independent test cohort) and accuracy (88.24% in the validation cohort and 87.50% in the independent test cohort) for diagnosing TNs. This performance surpassed the specificity and accuracy observed with ultrasonography. A TN diagnostic and treatment framework that prioritizes patients is provided, with fine-needle aspiration (FNA) biopsy performed only on patients with indications of MTNs in both BLDM and ultrasonography results, thus avoiding unnecessary biopsies. CONCLUSIONS: This is the first study to demonstrate the potential of non-invasive blood leukocytes in diagnosing TNs, thereby making TN diagnosis and treatment more efficient in China.


Asunto(s)
Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/genética , Estudios Prospectivos , Inteligencia Artificial , Ultrasonografía , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/cirugía , Estudios Retrospectivos
20.
Pediatr Transplant ; 28(3): e14737, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38602290

RESUMEN

BACKGROUND: Venous complications after pediatric liver transplantation seriously affect the survival rate of patients and grafts. At present, the diagnostic indicators have not been unified. Venous complications may cause portal hypertension, which may lead to splenomegaly and splenic vein dilatation. Therefore, the changes in spleen may be closely related to the venous complications. The purpose of this study was to explore the relationship between ultrasonic splenic parameters and venous complications and to study whether these splenic parameters can be used for the diagnosis of venous complications. METHODS: We retrospectively included pediatric patients who underwent liver transplantation and collected ultrasonic spleen parameters before, and then 1-3 days, 1-3 weeks, 1-3 months, and 4-12 months after liver transplantation. We observed whether there were portal vein or hepatic vein complications within 1 year after liver transplantation. RESULTS: Among 109 pediatric patients after liver transplantation included in our study, 11 of them suffered from portal vein complications and nine hepatic vein complications. Spleen transverse diameter, spleen longitudinal diameter, spleen portal vein diameter, spleen index, spleen transverse diameter ratio, spleen longitudinal diameter ratio, and spleen index ratio were independent risk factors of venous complications. The accuracy of spleen transverse diameter (AUROC: 0.73), spleen index (AUROC: 0.70), spleen transverse diameter ratio (AUROC: 0.71), and spleen index ratio (AUROC: 0.72) in predicting venous complications were higher than other ones. CONCLUSIONS: Ultrasonic examination is a common follow-up method for pediatric patients after liver transplantation and the application of ultrasonic spleen parameters may be helpful to monitor venous complications.


Asunto(s)
Trasplante de Hígado , Bazo , Humanos , Niño , Bazo/diagnóstico por imagen , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/métodos , Estudios Retrospectivos , Vena Porta/diagnóstico por imagen , Ultrasonografía , Vena Esplénica/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...